波兰索耐SONEL/MZC-330S高电流回路阻抗计

波兰索耐sonel/mzc-330s高电流回路阻抗计|京海兴乐科技(北京)有限公司提供
mzc - 330 s
指数:wmgbmzc330
高电流回路阻抗计
mzc-330s
index: wmgbmzc330
high-current loop impedance meter
测量短路回路阻抗非常低(与分辨率0 1 mω)的电流在230 v 130;大300在750 v或230 v,电流24大30 750 v(与分辨率0 01ω)
额定电压110/190 v、115/200 v、127/220 v、220/380 v、230/400 v、240/415 v、290/500 v和400/690 v之间,频率45…65赫兹,
能够在短路系统中进行测量:相相,相保护,相中性,
计算短路电流时相电压和相间电压的区别,
改变测试引线长度的能力,
四极法,测试引线不需要校准(测量电流为300a)。
接触电压和触觉冲击电压测量电阻1 kω)。
交流电压测量范围为0…750v。
有能力转移数据到个人电脑的999测量结果的记忆体
通过usb和蓝牙传输数据的能力。
仪表符合en61557标准的要求。
voltage measurements (true rms)
rangeresolutionaccuracy
0...750 v 1 v ±(2% m.v. + 2 digits)
frequency range: dc, 45...65 hzinput impedance of the voltmeter:>200 kωfrequency measurements (for voltages in range 95...750 v)
rangeresolutionaccuracy
45,0...65,0 hz 0,1 hz ±(0,1% m.v. + 1 digit)
short circuit loop parameters measurement using high current (4p, imax=300 a)
high-current of measurement of short circuit loop impedance zs:
measuring range according to iec61557:7,2 mω...1999 mω
rangeresolutionaccuracy
0...199,9 mω 0,1 mω ±(2% m.v. + 2 mω)
200...1999 mω 1 mω ±(2% m.v. + 2 mω)
short circuit resistance r and reactance xsdisplay range
rangeresolutionaccuracy
0...199,9 mω 0,1 mω ±(2% m.v. + 2 mω) impedance reading for a particular measurement
200...1999 mω 1 mω ±(2% m.v. + 2 mω) impedance reading for a particular measurement
short circuit current indication
measuring range according to iec 61557:
for un= 230 v 115,0 a...32,0 kafor un= 400 v 200 a...55,7 kafor un= 500 v 250 a...69,4 kafor un = 690 v 345 a...95,8 karangeresolutionaccuracy
115,0...199,9 a 0,1 a accuracy of the curren indication computed, respectively, with the use of resistance measurements
200...1999 a 1 a accuracy of the curren indication computed, respectively, with the use of resistance measurements
2,00...19,99 ka 0,01 ka accuracy of the curren indication computed, respectively, with the use of resistance measurements
20,0...199,9 ka 0,1 ka accuracy of the curren indication computed, respectively, with the use of resistance measurements
200 ka...* 1 ka accuracy of the curren indication computed, respectively, with the use of resistance measurements
* 230 ka for ul-n
400 ka for ul-l
short circuit loop parameters measurement using standards current (2p, imax=30 a)
touch voltage measurements ustand shock voltage ut
rangeresolutionaccuracy
0...100 v 1 v ±(10% m.v. + 2 digits)
short circuit loop impedance zsmeasurement:
measuring range according to iec61557:0,13 ω...199,9 ωfor test leads length 1,2 m
rangeresolutionaccuracy
0,00...19,99 ω 0,01 ω ±(2% m.v. + 3 digits)
20,0...199,9 ω 0,1 ω ±(3% m.v. + 3 digits)
short circuit resistance rsand reactance xsdisplay range
rangeresolutionaccuracy
0,00...19,99 ω 0,01 ω ±(2% m.v. + 3digits) impedance reading for a particular measurement
20,0...199,9 ω 0,1 ω ±(3% m.v. + 3 digits) impedance reading for a particular measurement
readings short circuit current
rangeresolutionaccuracy
1,150...1,999 a 0,001 a accuracy of the current indication computed, respectively, with the use of resistance measurements
2,00...19,99 a 0,01 a accuracy of the current indication computed, respectively, with the use of resistance measurements
20,0...199,9 a 0,1 a accuracy of the current indication computed, respectively, with the use of resistance measurements
200...1999 a 1 a accuracy of the current indication computed, respectively, with the use of resistance measurements
2,00...19,99 ka 0,01 ka accuracy of the current indication computed, respectively, with the use of resistance measurements
20,0...40,0 ka 0,1 ka accuracy of the current indication computed, respectively, with the use of resistance measurements
“m.v。——测量值。
电气安全:
绝缘类型:双绝缘,符合pn-en 61010-1和iec 61557;
测量类别:iv 600v acc。pn-en 61010 - 1;
acc保护类。pn-en 60529: ip20 (ip67前盖关闭);
其他技术数据:
电源:内置锂离子7,2v / 8,8ah
电阻器限制电流:
4杆方法4 p: 1、8ω;
两杆方法2 p: 9日4ωu≤253 v, 19ωu > 253 v,
短路环数测量:2000 (4/min.),
温度系数:±0,1%实测值/℃;
尺寸:390毫米x310毫米x170毫米;
重量:6 6公斤
额定操作条件:
操作温度0…+ 40°c
京海兴乐科技(北京)有限公司
公司主要提供ut(超声)mt(磁粉)pt(渗透)rt(射线)等设备及周边耗材
主要经营品牌:美国奥林巴斯olympus(原泛美)、美国ge(原德国kk)、美国磁通magnaflux
超声电子、siui、瑞典兰宝、美国sp公司、美国达高特、德国mr、英国易高、新美达、船牌、等等
提供的无损检测仪器设备主要有超声波探伤仪、相控阵探伤仪、超声波测厚仪、tofd探伤仪、超声波探头、相控阵探头、涡流探伤仪、涡流探头、涡流阵列探伤仪、磁粉探伤仪、磁粉、紫外线灯、照度计、工业扫查器、航空航天检测系统、着色渗透剂、荧光渗透线、工业内窥镜、工业显微镜、光谱(合金)分析仪、工业x光机、工业ct、cr、dr、工业洗片机、管材的无损检测解决方案、复合材料超声波自动化检测、超声波板材/管材检测系统、大型压力容器超声波检测系统、汽车点焊超声波检测设备,以及其它各类型分析检测仪器。
*以来,依托高素质的技术人员和销售队伍,本着诚信守法,客户*的经营原则,以良好的信誉、丰富的经验、周到的服务,为客户提供了*的检测设备及技术解决方案,赢得了国内外广大用户的信赖和好评。我们提供的设备、系统及方案应用于中国的各种*工业领域,
用户行业包括航空航天,核能电力,船舶制造,海洋石油,石油化工,机械制造,铁路交通,进口商检,技术监督,高校及研究机构等。依托高素质的技术人员和销售队伍,本着守法,诚信,客户*的经营原则,公司以良好的信誉,周到的售前和售后服务,赢得了广大用户的信赖和好评。

ZZWPE自力式温度调节阀技术特点
塑料桶生产对注塑机的一些性能要求
哈氏可麿性测定仪的操作说明
链轮传动刀型闸阀
提高液下渣浆泵抗气蚀性能的措施
波兰索耐SONEL/MZC-330S高电流回路阻抗计
自动漆膜干燥时间测定仪使用方法与维护
目前电缆桥架该不该装防火隔板,我觉得防火材料不少
GCQ-自洁式排气水过滤器的原理特点及用途
轨道球阀的设计原理及结构特点
H100-520压力开关厂家供应
先测负载-关于柴油发电机组的泰尔认证-容性功率
如何确定蒸发器的类型
喷淋式杀菌锅的工作原理及喷淋方式
二次元影像仪准确测量与问题排解办法
电池电压电路不均匀应该怎么处理
DIN标准1.4305不锈钢退火
数控大轮调整参数的确定及数控代码的编制
直流接地电阻故障测试仪查找方案与步骤
德国Burocco截止阀工作原理及特性